Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.513
Filtrar
1.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484087

RESUMO

CASE: We will present the case of a 6-year-old girl who presented with a 3-cm limb length discrepancy after intraosseous line placement at age 14 months without other known history of trauma or infection to account for the growth arrest. Imaging revealed a left proximal tibial physeal bar amenable to surgical resection with autologous lipotransfer. At 10 months postoperatively, physical examination and imaging demonstrated a stable 3-cm leg length discrepancy with an interval increase in the length of the left tibia in proportion to the growth of the right side with an increase in valgus alignment that will continue to be monitored and addressed as indicated. CONCLUSION: Pediatric intraosseous line placement presents unique challenges and can ultimately lead to physeal injury and growth arrest in the case of malpositioning.


Assuntos
Lâmina de Crescimento , Tíbia , Criança , Feminino , Humanos , Lâmina de Crescimento/cirurgia , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
2.
Arch Orthop Trauma Surg ; 144(4): 1503-1509, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38353685

RESUMO

INTRODUCTION: The use of magnetic resonance imaging (MRI) with a magnetic intramedullary lengthening nail in place is contraindicated per the manufacturer due to the concern of implant activation and migration. A prior in vitro study did not confirm these complications only noting that a 3.0 T MRI weakened the internal magnet. Therefore, a retrospective analysis of patients who underwent an MRI with a magnetic nail in place was performed to determine if any adverse effects occurred in the clinical setting. MATERIALS AND METHODS: A retrospective review of all patients who underwent an MRI with a magnetic lengthening nail in place was performed. The time spent being imaged in the MRI, number of times the patient entered the MRI suite, and the images obtained were recorded. Radiographs were performed before and after the MRI to determine if any hardware complications occurred. The patients were monitored for any adverse symptoms while they were in the suite. RESULTS: A total of 12 patients with 13 nails were identified. Two patients underwent imaging with a 3.0 T MRI while the remaining 10 underwent imaging with a 1.5 T MRI. Each patient entered the MRI suite 2.1 times and spent an average of 84.7 min being imaged in the MRI (range 21-494). No patients noted any adverse symptoms related to the nail while in the suite and no hardware complications were identified. CONCLUSION: MRI appears to be safe with a magnetic nail in place and did not result in any complications. Given the manufacturer's recommendations, informed consent should be obtained prior to an MRI being performed and a 3.0 T MRI should be avoided when possible if further activation of the nail is required.


Assuntos
Alongamento Ósseo , Fixação Intramedular de Fraturas , Humanos , Alongamento Ósseo/métodos , Fêmur/cirurgia , Desigualdade de Membros Inferiores/cirurgia , Fixação Intramedular de Fraturas/métodos , Estudos Retrospectivos , Estudos de Viabilidade , Pinos Ortopédicos , Resultado do Tratamento , Imageamento por Ressonância Magnética
3.
Sci Rep ; 14(1): 717, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184715

RESUMO

Correction of leg length discrepancy (LLD) in skeletally mature patients with osteosarcoma was rarely reported and quite challenging. This study aimed to propose a treatment strategy of staged lengthening and reconstruction with a standard static prosthesis to address LLD and restore limb function. It also evaluated the effectiveness of the strategy in terms of leg lengthening, functional outcomes, and complications. The strategy for lengthening included three stages. In stage 1, the previous prosthesis was removed and an external fixator with a temporary rod-cement spacer was placed. In this stage, the external fixator was used to lengthen the limb to the appropriate length. In stage 2, the external fixator was removed and the old rod-cement spacer was replaced with a new one. In stage 3, the rod-cement spacer was removed and the standard static prosthesis was planted. Nine skeletally mature distal femoral osteosarcoma patients with unacceptable LLD were treated in our institution from 2019 to 2021. We performed a chart review on nine patients for the clinical and radiographic assessment of functional outcomes, LLD, and complications. The mean (range) leg lengthening was 7.3 cm (3.6-15.6). The mean (range) LLD of the lower limbs decreased from 7.6 cm (4.1-14.2) before the lengthening to 0.3 cm (- 0.3 to 2.1) at the final follow-up with statistical significance (P = 0.000). The mean (range) Musculoskeletal Tumor Society score improved from 30.3% (16.7%-53.3%) before the lengthening to 96.3% (86.7%-100%) at the final follow-up with statistical significance (P = 0.000). Three patients (33.3%) had a minor complication; none needed additional surgical intervention. In the short term, the current staged lengthening and reconstruction with standard static prosthesis provided satisfactory functional outcomes and LLD correction with few complications. The long-term effects of this method need further exploration.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Humanos , Perna (Membro)/cirurgia , Extremidade Inferior , Desigualdade de Membros Inferiores/cirurgia , Osteossarcoma/cirurgia , Neoplasias Ósseas/cirurgia
4.
Acta Orthop ; 95: 47-54, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38287909

RESUMO

BACKGROUND AND PURPOSE: Bilateral femoral distraction osteogenesis in patients with achondroplasia is insufficiently reported. We aimed to perform the first study that exclusively analyzed simultaneous bilateral femoral distraction osteogenesis with motorized intramedullary lengthening nails via an antegrade approach in patients with achondroplasia focused on reliability, accuracy, precision, and the evolving complications. PATIENTS AND METHODS: In this retrospective singlecenter study we analyzed patients with achondroplasia who underwent simultaneous bilateral femoral lengthening with antegrade intramedullary lengthening nails between October 2014 and April 2019. 15 patients (30 femoral segments) of median age 14 years (interquartile range [IQR] 12-15) were available for analysis. The median follow-up was 29 months (IQR 27-37) after nail implantation. RESULTS: The median distraction length per segment was 49 mm (IQR 47-51) with a median distraction index of 1.0 mm/day (IQR 0.9-1.0), and a median consolidation index of 20 days/cm (IQR 17-23). Reliability of the lengthening nails was 97% and their calculated accuracy and precision were 96% and 95%, respectively. The most common complication was temporary restriction of knee range of motion during distraction in 10 of 30 of the lengthened segments. 1 patient was treated with 2 unplanned additional surgeries due to premature consolidation. CONCLUSION: The method is reliable and accurate with few complications.


Assuntos
Acondroplasia , Alongamento Ósseo , Fixação Intramedular de Fraturas , Osteogênese por Distração , Humanos , Adolescente , Osteogênese por Distração/efeitos adversos , Osteogênese por Distração/métodos , Estudos Retrospectivos , Fixação Intramedular de Fraturas/métodos , Seguimentos , Unhas , Reprodutibilidade dos Testes , Fêmur/cirurgia , Alongamento Ósseo/métodos , Acondroplasia/complicações , Acondroplasia/cirurgia , Pinos Ortopédicos/efeitos adversos , Resultado do Tratamento , Desigualdade de Membros Inferiores/cirurgia
5.
Hip Int ; 34(1): 134-143, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37128124

RESUMO

PURPOSE: The aim of the study was to determine the restoration of hip biomechanics through lateral offset, leg length, and acetabular component position when comparing non-arthroplasty surgeons (NAS) to elective arthroplasty surgeons (EAS). METHODS: 131 patients, with a femoral neck fracture treated with a THA by 7 EAS and 20 NAS, were retrospectively reviewed. 2 blinded observers measured leg-length discrepancy, femoral offset, and acetabular component position. Multivariate logistic regression models examined the association between the surgeon groups and restoration of lateral femoral, acetabular offset, leg length discrepancy, acetabular anteversion, acetabular position, and component size, while adjusting for surgical approach and spinal pathology. RESULTS: NAS under-restored 4.8 mm of lateral femoral offset (43.9 ± 8.7 mm) after THA when compared to the uninjured side (48.7 ± 7.1 mm, p = 0.044). NAS were at risk for under-restoring lateral femoral offset when compared to EAS (p = 0.040). There was no association between lateral acetabular offset, leg length, acetabular position, or component size and surgeon type. CONCLUSIONS: Lateral femoral offset is at risk for under-restoration after THA for femoral neck fractures, when performed by surgeons that do not regularly perform elective THA. This indicates that lateral femoral offset is an under-appreciated contributor to hip instability when performing THA for a femoral neck fracture. Lateral femoral offset deserves as much attention and awareness as acetabular component position since a secondary analysis of our data reveal that preoperative templating and intraoperative imaging did not prevent under-restoration.


Assuntos
Artroplastia de Quadril , Fraturas do Colo Femoral , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia
6.
J Bone Joint Surg Am ; 106(2): 145-150, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37972990

RESUMO

BACKGROUND: The Modified Fels (mFels) and Abbreviated Modified Fels (abFels) knee systems have been recently developed as options for grading skeletal maturity without the need for a separate hand radiograph. We sought to determine the interobserver reliability of these systems and to compare their prediction accuracy with that of the Greulich and Pyle (G-P) atlas in a cohort managed with epiphysiodesis for leg-length discrepancy (LLD). METHODS: Three reviewers scored 20 knee radiographs using the mFels system, which includes 5 qualitative and 2 quantitative measures as well as a quantitative output. Short leg length (SL), long leg length (LL), and LLD prediction errors at maturity using the White-Menelaus (W-M) method and G-P, mFels, or abFels skeletal age were compared in a cohort of 60 patients managed with epiphysiodesis for LLD. RESULTS: Intraclass correlation coefficients for the 2 quantitative variables and the quantitative output of the mFels system using 20 knee radiographs ranged from 0.55 to 0.98, and kappa coefficients for the 5 qualitative variables ranged from 0.56 to 1, indicating a reliability range from moderate to excellent. In the epiphysiodesis cohort, G-P skeletal age was on average 0.25 year older than mFels and abFels skeletal ages, most notably in females. The majority of average prediction errors between G-P, mFels, and abFels were <0.5 cm, with the greatest error being for the SL prediction in females, which approached 1 cm. Skeletal-age estimates with the mFels and abFels systems were statistically comparable. CONCLUSIONS: The mFels skeletal-age system is a reproducible method of determining skeletal age. Prediction errors in mFels and abFels skeletal ages were clinically comparable with those in G-P skeletal ages in this epiphysiodesis cohort. Further work is warranted to optimize and validate the accuracy of mFels and abFels skeletal ages to predict LLD and the impact of epiphysiodesis, particularly in females. Both the mFels and abFels systems are promising means of estimating skeletal age, avoiding additional radiation and health-care expenditure. LEVEL OF EVIDENCE: Prognostic Level II . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Desigualdade de Membros Inferiores , Perna (Membro) , Feminino , Humanos , Reprodutibilidade dos Testes , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/cirurgia , Extremidade Inferior , Fêmur , Determinação da Idade pelo Esqueleto/métodos
7.
Int Orthop ; 48(2): 473-479, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37715062

RESUMO

PURPOSE: Operative approach in total hip arthroplasty (THA) has long been a topic of debate with each approach having unique benefits and disadvantages. One purported benefit of an anterior approach to THA is that it allows for intraoperative positioning using fluoroscopy rather than manual positioning. Proper positioning allows for improved outcomes including leg length discrepancy and acetabular component angle. This study aims to examine if operative approach and use of imaging in intraoperative positioning impact LLD and cup angle post-operatively. METHODS: A total of 300 hips were enrolled in the study with 100 hips per approach (anterior with fluoroscopy, lateral, and posterior). Retrospective chart review was conducted to assess patient demographics and radiographic analysis used to determine LLD and acetabular cup angle. RESULTS: Of the three groups, those receiving anterior approach THAs were on average older than those in the posterior group. Analysis comparing the LLD and acetabular angle across the three groups showed no statistically significant difference in LLD (p=0.091); this was also reflected when comparing hips that received fluoroscopy with those that did not (p=0.91). For acetabular angle, while no difference existed when comparing hips that received imaging versus those that did not, statistically significant differences were observed when comparing the three intraoperative approaches (p<0.0001). CONCLUSIONS: Neither intraoperative approach nor the use of intraoperative imaging in THA has a statistically significant effect on LLD post-operatively. However, approach did impact the acetabular cup angle across all three distinct approaches.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Estudos Retrospectivos , Perna (Membro) , Posicionamento do Paciente , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/cirurgia
8.
J Pediatr Orthop ; 44(1): e57-e60, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37867312

RESUMO

BACKGROUND: Few studies address frequency or magnitude of healthy lower-extremity segment response to ipsilateral companion segment shortening. We sought to document and quantify this occurrence in a variety of pediatric etiologies. METHODS: We reviewed the medical record and radiographs of patients undergoing epiphysiodesis to manage leg length discrepancy. Inclusion criteria for this study were leg length discrepancy of a single lower-extremity segment by identifiable cause and adequate scanograms to allow accurate measurement of all 4 lower-extremity segments before any surgical treatment for the discrepancy. We recorded the etiology of shortening, age of onset of disorder, the length of the lower-extremity segments on scanograms, and age at the time of radiographs. We considered ipsilateral healthy-segment difference from the contralateral ≥ 0.5 cm. as clinically significant. RESULTS: Two hundred nine patients met inclusion criteria (126 boys, 83 girls). The average age was 12.5 years. 16/60 patients with avascular necrosis of the hip demonstrated ipsilateral tibial shortening averaging 1.2 cm whereas 6/60 demonstrated ipsilateral tibial overgrowth averaging 0.6 cm. 11/30 Legg-Perthés patients demonstrated ipsilateral tibial shortening averaging 0.7 cm; none had ipsilateral tibial overgrowth. 10/42 posteromedial bow patients had ipsilateral femoral shortening averaging 0.8 cm, whereas 6/42 had ipsilateral overgrowth averaging 0.8 cm. 13/48 with distal femoral physeal injury demonstrated ipsilateral tibial shortening averaging 1.2 cm, whereas 6/48 demonstrated ipsilateral tibial overgrowth averaging 0.8 cm. 8/29 tibial physeal injuries (proximal or distal) demonstrated ipsilateral femoral shortening averaging 1.1 cm. whereas 7/29 demonstrated ipsilateral femoral overgrowth averaging 0.7 cm. CONCLUSIONS: Although there are individual exceptions, the ipsilateral healthy segment does not grow appreciably more than the contralateral in patients with avascular necrosis of the hip, Legg-Perthés disease, or physeal trauma. The femur is not a significant component of shortening in patients with posteromedial bow. LEVEL OF EVIDENCE: Level III, retrospective review.


Assuntos
Perna (Membro) , Osteonecrose , Masculino , Feminino , Humanos , Criança , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Extremidade Inferior , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia , Estudos Retrospectivos
9.
Instr Course Lect ; 73: 369-385, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090910

RESUMO

Motorized intramedullary lengthening nails allow for transport of a bone segment for limb lengthening, deformity correction, healing of nonunion, and intercalary distraction osteogenesis. Resection of tumors involving the bone can result in substantial defects that require reconstruction. Use of these nails allows for a biologic reconstruction with the incorporation of allograft or by distraction osteogenesis. Limb lengthening after an internal hemipelvectomy where the hip joint is resected can be performed to improve gait, decrease pain, and prevent the need for a custom shoe or shoe lift. Using these nails in compression aids the incorporation of intercalary allografts and prevents stress shielding and stress risers within the graft when compared with plating. It also allows for a subsequent lengthening of the limb using the same implant. Plate-assisted bone segment transport or the use of a bone transport nail allows for a true biologic reconstruction of an intercalary defect using distraction osteogenesis. These implants provide the orthopaedic oncologist with more options for reconstruction and the potential to improve the function and outcomes of their patients.


Assuntos
Produtos Biológicos , Fixação Intramedular de Fraturas , Osteogênese por Distração , Humanos , Desigualdade de Membros Inferiores/cirurgia , Resultado do Tratamento , Pinos Ortopédicos , Fêmur/cirurgia
10.
Injury ; 54 Suppl 6: 110838, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38143138

RESUMO

BACKGROUND: To evaluate the clinical outcomes using the PRECICE magnetic limb lengthening intramedullary nail for the correction of lower limb length discrepancies (LLD) in adults with posttraumatic nonunion or malunion defects in a Latin American center. METHODS: A retrospective review of 25 adult patients with LLD associated with posttraumatic nonunion or malunion defects of femur or tibia treated with the PRECICE nail between January 2018 and December 2020. The primary outcomes considered were lengthening length achieved in mm, incidence of complications and quality of life (EQ-5D-3 L questionnaire). RESULTS: Twenty-five cases (20 femoral and 5 tibial nails) were performed, with a median follow-up of 27 months (Interquartile range-IQR: 17.5 to 34.5). The average age was 36.5 ± 12.9 years; 10 cases were women. Fifteen cases had an LLD secondary to a malunion defect and 10 cases had an LLD secondary to a nonunion. PRECICE nails were inserted for the treatment of a median LLD of 40.0 mm (IQR: 30.2 to 74.2) in the femur and 30.0 mm (28.5 to 50.0) in the tibia. An accuracy of 100% was reported in 18 cases (Femur: 14 and tibia: 4) and consolidation was achieved in 22/25 cases with the PRECICE nail in situ. Complications were recorded in 9 (36%) cases (6/20 femur, 3/5 tibia), mainly related to the consolidation process (5/9). The median EQ-5D and EQ-VAS were 0.79 (IQR: 0.63 to 0.79) and 80.0 (IQR: 50.0 to 90.0), respectively. CONCLUSIONS: The results of this study demonstrated that the PRECICE nail is an effective device for the management of posttraumatic LLD during the treatment of nonunion or malunion bone defects of femur and tibia, offering a reasonable quality of life, despite its postoperative complication risk.


Assuntos
Alongamento Ósseo , Adulto , Humanos , Feminino , Adulto Jovem , Pessoa de Meia-Idade , Masculino , Desigualdade de Membros Inferiores/cirurgia , América Latina , Qualidade de Vida , Resultado do Tratamento , Pinos Ortopédicos/efeitos adversos , Fêmur/cirurgia , Extremidade Inferior , Estudos Retrospectivos
11.
Can Vet J ; 64(11): 1002-1008, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37915782

RESUMO

Our objective was to report the use of distraction osteogenesis at the site of angular limb deformity correction using external skeletal fixation for treatment of 1 femoral and 1 tibial angular limb deformity in 2 large-breed puppies. Medical records were reviewed from 2 dogs (a 7-month-old intact male golden retriever and a 4-month-old intact female German shepherd mixed breed) diagnosed with angular limb deformities and truncation of a pelvic limb. Surgical treatment consisted of neutral wedge ostectomy and distraction osteogenesis at the site of bone deformity with an external skeletal fixator (ESF). The surgical technique and postoperative period of distraction osteogenesis were reviewed along with postoperative complications and clinical outcomes after complete bone healing was evident radiographically. Both dogs had adequate bone formation during distraction osteogenesis and the ESFs remained intact and structurally stable. At ESF removal, femoral length had increased 2.6 cm for Dog 1 and tibial length increased 3.88 cm for Dog 2, distal femoral valgus improved 16.3 degrees for Dog 1, and tibial procurvatum improved 19.5 degrees and distal tibial valgus improved 6.2 degrees for Dog 2. At the last follow-up examinations, 5 mo (Dog 1) and 3 mo (Dog 2) postoperatively, both dogs were ambulating without any visible lameness. Key clinical message: Acute angular correction and subsequent distraction osteogenesis at the site of bone deformity and corrective ostectomy using an ESF enabled successful treatment of femoral (Dog 1) and tibial (Dog 2) truncation and angulation in 2 large-breed puppies. Optimal deformity correction and lengthening were achieved through distraction osteogenesis at the site of neutral wedge ostectomy, minimizing soft tissue dissection and risk for potential complications that can occur with bifocal deformity correction (i.e., correction of the deformity at 1 osteotomy/ostectomy and correction of bone length at another, remote osteotomy).


Ostéogenèse par distraction au site d'ostectomie en coin neutre pour déformation angulaire du membre postérieur chez 2 jeunes chiens. Notre objectif était de rapporter l'utilisation de l'ostéogenèse par distraction au niveau du site de correction de la déformation angulaire du membre par fixation squelettique externe pour le traitement d'une déformation angulaire fémorale et d'une déformation angulaire tibiale chez 2 chiots de grande race. Les dossiers médicaux ont été examinés concernant 2 chiens (un golden retriever mâle intact âgé de 7 mois et une femelle berger allemand intacte de race mixte âgée de 4 mois) diagnostiqués avec des déformations angulaires des membres et une troncature d'un membre pelvien. Le traitement chirurgical consistait en une ostéogenèse en coin neutre et une ostéogenèse par distraction au niveau du site de déformation osseuse avec un fixateur squelettique externe (FSE). La technique chirurgicale et la période postopératoire d'ostéogenèse par distraction ont été examinées ainsi que les complications postopératoires et les résultats cliniques après une guérison osseuse complète évidente radiographiquement.Les deux chiens présentaient une formation osseuse adéquate pendant l'ostéogenèse par distraction et les FSE restaient intacts et structurellement stables. Lors du retrait de le FSE, la longueur fémorale avait augmenté de 2,6 cm pour le chien 1 et la longueur tibiale de 3,88 cm pour le chien 2, le valgus fémoral distal s'était amélioré de 16,3 degrés pour le chien 1, le procurvatum tibial s'était amélioré de 19,5 degrés et le valgus tibial distal s'était amélioré de 6,2 degrés pour le chien 2. Lors des derniers examens de suivi, 5 mois (chien 1) et 3 mois (chien 2) postopératoires, les deux chiens marchaient sans aucune boiterie visible.Message clinique clé :La correction angulaire aiguë et l'ostéogenèse de distraction ultérieure au site de déformation osseuse et l'ostectomie corrective à l'aide d'un FSE ont permis un traitement réussi de la troncature et de l'angulation fémorale (chien 1) et tibiale (chien 2) chez 2 chiots de grande race. La correction et l'allongement optimaux de la déformation ont été obtenus grâce à l'ostéogenèse par distraction au site de l'ostectomie en coin neutre, minimisant la dissection des tissus mous et le risque de complications potentielles pouvant survenir avec la correction de la déformation bifocale (c'est-à-dire la correction de la déformation à 1 ostéotomie/ostectomie et la correction de la longueur de l'os à une autre ostéotomie distante).(Traduit par Dr Serge Messier).


Assuntos
Osteogênese por Distração , Cães , Masculino , Animais , Feminino , Osteogênese por Distração/veterinária , Osteogênese por Distração/métodos , Desigualdade de Membros Inferiores/cirurgia , Desigualdade de Membros Inferiores/veterinária , Fixadores Externos/veterinária , Extremidade Inferior , Fêmur/cirurgia , Tíbia/cirurgia , Resultado do Tratamento
12.
BMJ Case Rep ; 16(11)2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37963663

RESUMO

A man in his 30s was involved in a road traffic accident (RTA) and sustained a grade-IIIA distal femur fracture with acute loss of distal two-third of the femur. Initially, damage control surgery was done by an external fixator application. Later, staged limb reconstruction surgery was undertaken as a definitive procedure that involved bifocal distraction osteogenesis involving the proximal tibia and femur along with docking of the corticotomised femoral fragment onto the tibial plateau to achieve knee arthrodesis. The tibial and femoral regenerate together measured 25.8 cm at the end of distraction phase leaving behind a limb length discrepancy of 5 cm. Acute traumatic large bone loss is a rare presentation and is beset with unique management challenges. Limb reconstruction surgery (LRS) with LRS system provides flexibility to tackle individual case-based scenarios and helps achieve limb length, maintain alignment and restore function.


Assuntos
Osteogênese por Distração , Tíbia , Masculino , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Resultado do Tratamento , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Osteogênese por Distração/métodos , Fixadores Externos , Artrodese , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia
13.
J Orthop Surg Res ; 18(1): 844, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37936235

RESUMO

BACKGROUND: Fibular Hemimelia (FH) is the most common longitudinal limb deficiency. Significant limb length discrepancy (LLD) will necessitate long treatment times and multiple settings to compensate for LLD when associated with femoral shortening. This study evaluates the outcome of simultaneous femoral and tibial lengthening using the Ilizarov frame. METHODS: This retrospective study included the cases of 12 children with severe limb length discrepancy caused by combined FH and ipsilateral femoral shortening from May 2015 to August 2022. The total LLD ranged from 7 to 14.5 cm. All patients underwent single-session femoral and tibial lengthening using the Ilizarov ring external fixator technique. Additional procedures were performed in the same setting, including Achilles tendon lengthening, fibular anlage excision, peroneal tendons lengthening, and iliotibial band release. Follow-up ranged from 2 to 4 years. RESULTS: The planned limb lengthening was achieved in ten cases (83%). No cases of joint subluxation or dislocation were encountered. No neurovascular injury has occurred during the treatment course. In all cases, the bone healing index was better on the femoral side than on the tibia. Poor regeneration and deformity of the tibia occurred in two cases (16.6%). CONCLUSION: Simultaneous femoral and tibial lengthening using the Ilizarov fixator is a relatively safe procedure with the result of correction of total LLD in one session in a shorter time and less morbidity.


Assuntos
Alongamento Ósseo , Ectromelia , Técnica de Ilizarov , Criança , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Ectromelia/diagnóstico por imagem , Ectromelia/cirurgia , Ectromelia/complicações , Estudos Retrospectivos , Fíbula/cirurgia , Alongamento Ósseo/métodos , Desigualdade de Membros Inferiores/cirurgia , Desigualdade de Membros Inferiores/etiologia , Perna (Membro) , Resultado do Tratamento
14.
Acta Orthop Belg ; 89(2): 177-182, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37924532

RESUMO

Femoral shortening in children is a challenging condition with complex functional and psychological implications. We study the results of Ilizarov external fixator (IEF) lengthening compared to lengthening and then plating (LAP) in the management of femoral shortening in children. Forty patients were included in the study and equally divided randomly into 2 groups, in group I LAP was used and in group II lengthening by IEF only was done. The two groups were analyzed for postoperative variables to adjudge the surgical outcomes. The mean follow up time was 24.05 ± 2.99 months, The gained length was 5.60 ± 0.60 cm in group 1 and 5.48 ± 0.64 cm in group II, group I had a shorter external fixator period (3.96 ± 0.22) months, better healing index (24.6 ±2.76) days/cm, earlier complete weight-bearing (5.55 ± 0.78) months than group II. The period of hospitalization for group I was longer more than group II. The complications were less in group I (n=7, 35%) than in group II (n=11, 55%). There was no significant correlation between the healing index with age, also no significant difference was detected between the healing index and gender. There was a significant correlation between the gained length and complete weight-bearing. This study efficiently demonstrates that LAP may be better than lengthening with IEF alone in the management of femoral shortening in children.


Assuntos
Pinos Ortopédicos , Técnica de Ilizarov , Humanos , Criança , Resultado do Tratamento , Fixadores Externos , Fêmur/cirurgia , Desigualdade de Membros Inferiores/cirurgia
15.
BMC Musculoskelet Disord ; 24(1): 884, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37957622

RESUMO

PURPOSE: The position of the acetabular and femoral components is critical for stability and wear resistance. The aim of this study is to investigate whether the fluoroscopy-guided direct anterior approach in the supine position (S-DAA) is more helpful in improving the position of acetabular and femoral components than the fluoroscopy-guided direct anterior approach in the lateral decubitus position (L-DAA). METHODS: A retrospective analysis of 76 cases of fluoroscopy-guided direct anterior approach total hip arthroplasty (38 cases in the S-DAA and 38 cases in the L-DAA group) was performed in one hospital from 2019 to 2021. The differences in inclination, anteversion, femoral offset (FO), global offset (GO), and leg length discrepancy (LLD) measurements during and after surgery were analyzed. The postoperative femoral offset (FO), global offset (GO), leg length discrepancy (LLD), and preoperative and postoperative Harris hip score were compared between the two groups. RESULTS: In the S-DAA group, there were no significant differences in the mean intraoperative inclination angle anteversion angle, FO, GO, and LLD compared to the postoperative values, whereas in the L-DAA group, there were significant differences between the intraoperative and postoperative measurements (P < 0.001, P = 0.009, P<0.001, P<0.001 and P = 0.008, respectively). Additionally, there were significant differences in the accuracy of LLD, FO, and GO between the two groups (P < 0.001). Compared with the L-DAA group, the average differences of inclination, anteversion, LLD, FO, and GO during and after operation in the S-DAA group were smaller, and the consistency was higher. There was a significant difference in Harris hip score between the two groups at 1 week after surgery (P = 0.033). There was no significant difference in Harris hip score between 1 month and 3 months after surgery (P = 0.482 and P = 0.797, respectively). CONCLUSIONS: In the supine group, the direct anterior approach (DAA) provides more accurate positioning of the acetabular and femoral components. However, there was no significant difference in hip joint function and activity between the two groups at follow-up.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Decúbito Dorsal , Acetábulo/cirurgia , Fluoroscopia , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia
16.
BMC Musculoskelet Disord ; 24(1): 781, 2023 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-37789293

RESUMO

BACKGROUND: Patients with ankylosing spondylitis often have fusions in the spine and sacroiliac joints, such that it is difficult to compensate for leg length discrepancy (LLD). METHODS: We retrospectively measured the LLD after total hip arthroplasty (THA) in 89 patients with ankylosing spondylitis from June 2004 to February 2021 at our institute. Patients were divided into two groups based on an LLD of 5 mm. Clinical outcomes were investigated using the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and Harris Hip Score (HHS). In addition, these points are investigated: patient satisfaction with the operation; whether there was a current difference in leg length; and whether there was a limping gait. RESULTS: The group with an LLD of 5-10 mm rather than < 5 mm had significantly worse WOMAC pain and stiffness. The survey revealed statistically significant differences in patient satisfaction with the operation, limping gait, and whether back pain had improved. CONCLUSION: For patients with ankylosing spondylitis, reducing the LLD to < 5 mm, which is more accurate than the current standard of < 10 mm, may produce greater improvement in clinical outcomes after hip arthroplasty.


Assuntos
Artroplastia de Quadril , Espondilite Anquilosante , Humanos , Artroplastia de Quadril/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Perna (Membro) , Espondilite Anquilosante/complicações , Espondilite Anquilosante/cirurgia , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/cirurgia
17.
Sci Rep ; 13(1): 17161, 2023 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-37821499

RESUMO

While previous studies on navigated total hip replacement (nTHA) focused on acetabular component positioning, we compared the results of nTHA with conventional total hip replacement (cTHA) in respect of changes in leg length and hip offset. In a single-center study results radiographic parameters of patients with unilateral THA were included. Data were retrospectively analyzed from computer navigation data and radiographs. Analysis concentrated on the discrepancy in leg length (LLD) and hip offset (OSD) between the affected and unaffected hip. The effect of the procedure was defined as the difference between postoperative and preoperative LLD and OSD values in each group. 2332 patients were analyzed. Both nTHA and cTHA were effective in restoring LLD and OSD by reducing the preoperative value significantly (p < 0.001). Regarding changes in LLD, no statistical difference between nTHA and cTHA could be found. Changes in OSD nTHA was a slightly more effective than cTHA (- 2.06 ± 6.00 mm vs. - 1.50 ± 5.35 mm; p < 0.05). Both navigated and conventional THA were successful in reconstruction of leg length and hip offset, while postoperative offset discrepancy was significantly lower in the navigated group at the cost of longer operation times. If these results are clinically relevant further investigation is needed.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Perna (Membro)/cirurgia , Estudos Retrospectivos , Desigualdade de Membros Inferiores/diagnóstico por imagem , Desigualdade de Membros Inferiores/cirurgia , Acetábulo/cirurgia
18.
BMC Musculoskelet Disord ; 24(1): 648, 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573304

RESUMO

PURPOSE: Postoperative limb length discrepancy (LLD) is a common complication of total hip arthroplasty, and several methods exist to prevent LLD, but each has its benefits and drawbacks. The study investigates the application of intraoperative lower limb length measurement in preventing postoperative LLD. METHODS: This study retrospectively analyzed 70 patients who underwent total hip arthroplasty from October 2018 to July 2022. The length of the lower limb on the operated side was measured intraoperatively using a sterilized paper ruler after the fitting of the trial mould and compared with the healthy side. Then the prosthesis size, depth and neck length were adjusted accordingly. RESULTS: The absolute value of postoperative LLD was found to be 6.68 ± 4.48 mm, of which 53 cases (75.7%) were less than or equal to 10 mm, while 30 patients (42.9%) were less than or equal to 5 mm. CONCLUSION: The use of intraoperative measurement is effective in reducing LLD after total hip arthroplasty.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/prevenção & controle , Desigualdade de Membros Inferiores/cirurgia , Extremidade Inferior/cirurgia , Período Pós-Operatório
19.
Orthopadie (Heidelb) ; 52(9): 719-728, 2023 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-37561147

RESUMO

For paediatric orthopaedic surgeons treating leg length discrepancy, knowledge of the available procedures and their options and limits is just as important as mastery of the very different surgical methods and implants, as well as the possible complications, in order to be able to advise and treat the children and adolescents and their parents comprehensively and in the best interests. Both the growth inhibiting procedures and the complex bone lengthening procedures require a great deal of experience to successfully guide patients and families through what is often a lengthy and sometimes complicated treatment process. Careful preoperative indications and planning, precise surgical techniques with suitable instruments and implants, and attentive postoperative check-ups are mandatory prerequisites for the desired therapeutic success.


Assuntos
Alongamento Ósseo , Ortopedia , Adolescente , Humanos , Criança , Perna (Membro)/cirurgia , Alongamento Ósseo/efeitos adversos , Desigualdade de Membros Inferiores/cirurgia , Próteses e Implantes/efeitos adversos
20.
Orthop Surg ; 15(9): 2373-2382, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37519271

RESUMO

OBJECTIVE: The high hip center (HHC) technique has been proposed for the treatment of patients with developmental dysplaisa of the hip (DDH) who have an acetabular bone defect. However, the importance of global femoral offset (FO) in the application of this technique has not been sufficiently appreciated. Our goals were to confirm that the HHC technique is feasible in the treatment of patients with DDH and to assess the function of global FO in this procedure. METHODS: We retrospectively analyzed 73 patients who underwent total hip arthroplasty using high hip center technique for unilateral DDH at our hospital between January 2014 and June 2019. According to global FO, the patients were split into three groups: increased FO group (increment greater than 5 mm), restored FO group (restoration within 5 mm) and decreased FO group (reduction greater than 5 mm). Patients' medical records and plain radiographs were reviewed. One-way ANOVA was used to compare radiographic outcomes and Harris hip score (HHS). Paired t-test was used to assess preoperative and postoperative HHS and leg length discrepancy. Trochanteric pain syndrome, Trendelenburg sign and postoperative limp was evaluated with Fisher's exact test. RESULTS: The average follow-up time was 7.5 ± 1.4 years. The patients' HHS and leg length discrepancy were significantly improved (p < 0.05). In terms of vertical acetabular height, abductor arm, postoperative leg length difference, and acetabular cup inclination, there was no statistically significant difference between the three groups. At the last follow-up, HHS was significantly higher in the restored FO group than in the decreased FO and increased FO groups. Trochanteric pain syndrome occurred in 15.0% and Trendelenburg sign and postoperative limp in 8.2% of all patients, respectively. Trochanteric pain syndrome, Trendelenburg sign and postoperative limp did not differ significantly across the three groups. One patient in increased FO group underwent revision for dislocation 6 years after surgery. CONCLUSION: The HHC technique is an alternative technique for total hip arthroplasty in patients with acetabular bone abnormalities, according to the results of the mid-term follow-up. Also, controlling the correction of the global femoral offset to within 5 mm may lead to better clinical outcomes.


Assuntos
Artroplastia de Quadril , Luxação Congênita de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur/cirurgia , Acetábulo/cirurgia , Desigualdade de Membros Inferiores/cirurgia , Dor/etiologia , Resultado do Tratamento , Luxação Congênita de Quadril/cirurgia , Seguimentos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...